Repair and service Audi A8 in body D2 with 1994 for 1999 of release.
1. Car operation
2. Maintenance service
3. Petrol engines of 2,8 l
4. Petrol engines of 3,7 and 4,2 l
5. Diesel engines of 2,5 l
6. Diesel engines of 3,3 l
7. Systems of ignition and injection of fuel of petrol engines
8. System of release of the fulfilled gases of cars with petrol engines
9. The power supply system of diesel engines
10. System of prestarting heating of diesel engines
11. System of release of the fulfilled gases of cars with diesel engines
12. Greasing system
13. Cooling system
14. Coupling
15. A transmission
16. Shaft of a drive of forward wheels
17. Features of a design of transmission of all-wheel drive cars
18. A suspension bracket
19. Wheels and tyres
20. A steering
21. Brake system
22. A body
23. Heating and air-conditioning system
23.1. The general data
23.2. An air inlet with a folding shutter
23.3. The fan
23.4. The fan resistor
23.5. The pollen filter
23.6. The central ventilating lattices
23.7. A lateral ventilating lattice
23.8. The top lateral ventilating lattice
23.9. A lateral nozzle of defrosting
23.10. The block of management E87 a central air
23.11. An arm of the compressor of the conditioner
24. An electric equipment
25. Electric schemes
 










23-2-vozdukhozabornik-s-otkidnojj-stvorkojj.html

23.2. An air inlet with a folding shutter

Removal
Remove a casing of the ventilating chamber.

Fig. 17–2. An air inlet with a folding shutter: 1 – a lattice; 2 – the inlet channel; 3 – a folding shutter; 4 – the case


Remove a lattice 1 (fig. 17–2) from an air inlet.
Switch off ignition.
Disconnect a cable of management from an air inlet shutter.
Unscrew three bolts And and In (fig. 17–3) and disconnect a clip From fastening of a cover of a cable to the air inlet case.

Fig. 17–3. An arrangement of bolts (And,) fastenings of the inlet channel and a clip () fastenings of a cover of a cable of management



Remove the air inlet channel from the car.

Installation
Installation is spent to sequences, return to removal, taking into account the following.
Before installation of the inlet channel put hermetic D, 176 001 A3 in places With and

Fig. 17–4. Places of drawing of hermetic D 176 001 A3 before installation of the inlet channel

D shown on fig. 17–4.

Fig. 17–5. The Installation site of additional soft rubber consolidation on a flange of the case of the inlet channel



If the windscreen mists over, lay soft rubber consolidation in diameter of 3 mm on a flange of the case of the inlet channel (fig. 17–5).


23.1. The general data

23.3. The fan